A basic cored wire for use with argon / carbon dioxide or carbon dioxide shielding gas.
Specifications
Classifications | SFA/AWS A5.20 : E71T-5C H4 SFA/AWS A5.20 : E71T-5M H4 EN ISO 17632-A : T 42 3 B C1 2 H5 EN ISO 17632-A : T 42 3 B M21 2 H5 |
Approvals | CE : EN 13479 DB : 42.040.01 (M21 and C1) LR : 3YS H5 VdTÜV : 04442 |
Approvals are based on factory location. Please contact ESAB for more information.
Welding Current | DC- |
Diffusible Hydrogen | < 4 ml/100g |
Alloy Type | CMn steel |
Typical Tensile Properties | |||
Condition | Yield Strength | Tensile Strength | Elongation |
M21 shielding gas | |||
As Welded | 456 MPa | 569 MPa | 28 % |
Typical Charpy V-Notch Properties | ||
Condition | Testing Temperature | Impact Value |
M21 shielding gas | ||
As Welded | -30 °C | 129 J |
As Welded | -20 °C | 145 J |
Deposition Data | ||||
Diameter | Current | Voltage | Wire Feed Speed | Deposition Rate |
1.2 mm | 120-300 A | 16-32 V | 4.0-15.0 m/min | 1.7-6.5 kg/h |
1.6 mm | 140-400 A | 24-34 V | 3.0-10.5 m/min | 2.0-8.0 kg/h |
2.4 mm | 250-500 A | 28-38 V | 1.5-6.0 m/min | 3.5-9.5 kg/h |