An all-positional rutile cored wire for use with argon / 15-25% carbon dioxide shielding gas, providing very good toughness down to -40 °C. Can be used in all positions except vertical down.
Specifications
Classifications | SFA/AWS A5.29 : E81T1-Ni1M EN ISO 17632-A : T 46 3 1Ni P C1 2 H5 EN ISO 17632-A : T 46 4 1Ni P M21 2 H5 |
Approvals | ABS : 3YSAH5 (M21) BV : SA3YM (M21) CE : EN 13479 DNV-GL : IV Y46MS H5 (M21) LR : 4Y46S H5 (M21) |
Approvals are based on factory location. Please contact ESAB for more information.
Welding Current | DC+ |
Diffusible Hydrogen | < 5ml/100g |
Alloy Type | Low alloy steel (1% Ni) |
Typical Tensile Properties | |||
Condition | Yield Strength | Tensile Strength | Elongation |
M21 shielding gas | |||
As Welded | 560 MPa | 600 MPa | 25 % |
Typical Charpy V-Notch Properties | ||
Condition | Testing Temperature | Impact Value |
M21 shielding gas | ||
As Welded | -20 °C | 130 J |
As Welded | -30 °C | 120 J |
As Welded | -40 °C | 110 J |
Deposition Data | ||||
Diameter | Current | Voltage | Wire Feed Speed | Deposition Rate |
1.2 mm | 110-300 A | 21-32 V | 3.2-14.5 m/min | 1.3-5.8 kg/h |